Flexibility for Multicolor Panel Design
Optimizing immunophenotyping panels is a time consuming, iterative process. A number of markers are required to identify the populations of interest and then additional markers to interrogate function. Finding reagents that have the markers conjugated to fluorochromes detectable on the instrumentation available is another challenge. Ensuring that the reagent combination doesn’t compromise sensitivity often requires multiple rounds of empirical testing. A typical 12 color panel can require 1-4 months of design and optimization (1). The addition of a viability dye to the panel can prove crucial to obtaining the results needed. Having the flexibility to add a fixable viability dye in a variety of channels makes it easier to incorporate these into the design.
| Part Number | Reagent | Excitation/Emission (nm) | Excitation Laser | Bandpass |
|---|---|---|---|---|
| C36614 | ViaKrome 405 Fixable Viability Dye | 401/420 | Violet 405 nm | 450/45 |
| C36620 | ViaKrome 561 Fixable Viability Dye | 555/565 | Blue 488 nm | 585/42 |
| C36620 | ViaKrome 561 Fixable Viability Dye | 555/565 | Yellow Green 561 nm | 585/42 |
| C36624 | ViaKrome 638 Fixable Viability Dye | 638/655 | Red 638 nm | 660/10 |
| C36628 | ViaKrome 808 Fixable Viability Dye | 854/878 | Infrared 808 nm | 885/40 |
1. Mahnke, Y. , Chattopadhyay, P. and Roederer, M. (2010), Publication of optimized multicolor immunofluorescence panels. Cytometry, 77A: 814-818. doi:10.1002/cyto.a.20916
Полезные ссылки
-
Реагенты для научных исследований
- Cell Cycle Kit
- Принцип метода анализа клеточного цикла на проточном цитометре
- Оптимизированный протокол анализа клеточного цикла
- Протокол окрашивания клеточного цикла
- Многопараметрический анализ клеточного цикла
- Спектр возбуждения и флуоресценции йодида пропидия
- Эффективность Cell Cycle Kit
-
ViaKrome Fixable Viability Dyes
- Comparison of NHS ester-based reagents to ViaKrome Fixable Viability Dye
- Flexibility for Multicolor Panel Design
- Robust Performance
- ViaKrome Fixable Viability Dye Staining Protocol
- Why Use a Viability Dye?
- DNA Binding Dyes
- Apoptosis Reagents
- Research Assays
-
Проточная цитометрия
-
Проточные цитометры, сортеры клеток и станции пробоподготовки
- Проточный цитометр AQUIOS CL
- Navios EX Flow Cytometer
- Проточный цитометр DxFLEX
-
Проточный цитометр CytoFLEX
- CytoFLEX Startup User Guide
- Release Notes
- CytExpert Tools for 21 CFR Part 11 Compliance
- Compensation
- Consumables for the CytoFLEX Platform
- Focus
- Nanoparticle Detection
- Expand Violet, UV, or Near UV Channels with the CytoFLEX LX WDM Beam Splitter
- The CytoFLEX Platform
- Exquisite Sensitivity
- CytExpert Software for the CytoFLEX Platform
- CytoFLEX Technology
- Проточный цитометр CytoFLEX S
- Проточный цитометр CytoFLEX LX
- Клеточный сортер MoFlo Astrios EQ
- Проточный цитометр Navios
- Проточный цитометр Gallios
- Клеточный сортер MoFlo XDP
- nizonPLUS Cell Washer
- Станция пробоподготовки TQ-Prep
- Станция PrepPlus 2
-
Сбор данных, обработка результатов и управление данными
- AQUIOS Designer Software
-
Программное обеспечение Kaluza Analysis
- Kaluza Learning Center
- Инструкции по установке
- Kaluza Software Troubleshooting
- Kaluza Free Trial Download
- Build Analysis Workflows by Combining the Power of Kaluza Analysis Software and the Cytobank Platform
- Информация по версии
- Kaluza Cytobank Plugin Download
- R Console Plugin for Kaluza Analysis
- Автономный анализ
- Загрузки
- Функции Kaluza
- Программное обеспечение Kaluza С
- Программное обеспечение для сбора данных Kaluza for Gallios
- Анализатор спектров флуоресценции для проточной цитометрии
-
Проточные цитометры, сортеры клеток и станции пробоподготовки