Avanti® J-26S XPI Non-IVD Centrifuge with Elutriation, 50 Hz, 230 V

B14545


This build of the J36S upgrades the accel/decel profiles from 2/3 to 12/13 and includes elutriation particle separation. The J-26S XPI Centrifuge brings high speed, low heat output, imbalance tolerance and low noise. Above and beyond its BioSafety systems, this centrifuge has a more impact-resistant lid, full containment barrier and automatic rotor identification. Its ergonomic design--with lower instrument height and hands-free door operation--remains unchanged. The J-265 XPI Centrifuge processes up to six liters of fermentor output in less than 10 minutes, delivers a subcellular fraction at 82,000 x g, runs 24 microplates at a time and separates live cell populations with elutriation. It automatically detects which rotor is installed and prevents the rotor from running above its maximum-rated speed, and enables quicker, quieter, more energy-efficient runs with better temperature control. The exclusive high-torque, switched reluctance (SR) drive shortens cycle times.

Технические спецификации

Platform Avanti
Maximum Speed 26,000 rpm
Maximum g-Force |
BioSafe Нет
Acceleration Maximum, Slow or Timed (1-10 minutes, 0-500 rpm)
Deceleration Maximum, Slow, Timed (1-10 minutes from 500-0 rpm) or Off
Speed Control ± 10 rpm of set speed or 0.1%, whichever is greater
Timed Run 1 min to 99 hr 59min, W2t or Continuous hold
Max Capacity Volume Range 1 - 6 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Temperature Range(s) 10°C - 40°C in 1 degree increments
Rotor ID Automatic
Zonal Capability Да
Pollution Degree 2
Environmental Conditions -10°C to 40°C in 1° increments
Installation Category II
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Material(s) Steel, Plastic
Finish Powder Coat Paint
Weight 290 kg / 639.3 lb
Width 71 cm / 28 in
Depth 86.0, 102.0 with air direviter extending cm / 86.0, 102.0 with air direviter extending in
Height 86 cm (149 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Humidity Restrictions < 95% (non-condensing)
Power Requirements 230 VAC, 50 Hz

Посетители также интересовались

НЕ ВСЕ ПРОДУКТЫ ДОСТУПНЫ ВО ВСЕХ СТРАНАХ
ДОСТУПНОСТЬ И РЕГУЛЯТОРНЫЙ СТАТУС ПРОДУКЦИИ ЗАВИСИТ ОТ РЕГИСТРАЦИИ ПРОДУКТА В СООТВЕТСТВИИ С МЕСТНЫМ ЗАКОНОДАТЕЛЬСТВОМ

Что означает регулярный статус продукта:
IVD: In Vitro Diagnostic. Данная продукция предназначена для клинической диагностики in vitro.
ASR: Analyte Specific Reagents. Специфические аналитические реагенты. Аналитические и технические характеристики не установлены.
CE: Продукция, предназначенная для клинической диагностики in vitro и соответствующая директиве Европейского союза (98/79/EC). (Примечание: Оборудование может соответствовать другим директивам Европейского союза, и иметь соответствующую маркировку.)
RUO: Research Use Only. Данная продукция предназначена только для научных исследований и не предназначена для клинической диагностики.
LUO: Laboratory Use Only. Продукция предназначены только для лабораторного использования.
Без регуляторного статуса: немедицинские изделия и изделия, не подлежащие обязательной регистрации в регуляторных органах. Данная продукция не предназначена для клинического применения.