Allegra X-30R IVD 100V, 50/60 Hz Centrifuge

B06323


This IVD variation of the X-30R can be used in a clinical environment. Refrigerated model cools from room temperature to 4° C in fewer than ten minutes and has an operating temperature range of 2° C to 40° C (35° F to 104° F). The X-30R provides excellent performance and easy operation in a compact design that saves valuable time and laboratory space with the highest speed and g-force in its class (1.6L max capacity, 18,000 RPM, 29,756 x g). Simple and quick run setup. Versatile, with an extensive rotor library for multiple applications, plus a compact Design of only 18" wide (46cm). Includes a BioCertified* swinging-bucket and fixed-angle rotors. Rotor details: Three ways to spin the 1.5 mL PCR Tubes; Biocertified* 24-place fixed-angle rotor - 29,756 x g; 30-place fixed-angle rotor - 28,672 x g; 24-place swinging-bucket rotor - 16,244 x g for flat pelleting. One rotor spins 500 μL to 1.6 L; 4 x 400 mL - maximum capacity; 4,700 rpm - 4,255 x g - maximum g-force; 20 adapters. Spins the following labware: 400 mL bottles; 250 mL bottles; 100 mL, 94 mL, 85 mL bottles; 50 mL conical and round-bottom tubes; 15 mL conical and round-bottom tubes; 30 mL, 25 mL, 10 mL tubes; 1.5 mL and 500 μL PCR tubes. *BioCertified is a term used to describe products tested and validated to demonstrate containment of microbiological aerosols by an independent, third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment.

Технические спецификации

Platform Allegra 21
Maximum Speed 18,000 rpm with Fixed-Angle rotor (4,700 rpm with Swinging-Bucket rotor)
Acceleration 10 acceleration profiles
Deceleration 10 deceleration profiles
Speed Control ± 50 rpm of set speed
Timed Run To 9 hrs 59 mins or Continuous run (8)
Max Capacity Volume Range - 1600 mL
Refrigeration System Yes, CFC-Free
Speed Display Actual rotor speed in 100 rpm increments or in RCF (when selected)
Drive Type Cooling Brushless Induction
Temperature Range(s) From -20°C to 40°C in 1° increments
Friction Reduction System Asynchronous 3-phase Direct Drive
Installation Category II
Weight 78 kg / 172 lb
Width 46 cm / 18.1 in
Depth 70.7 cm / 27.8 in
Height 37 cm / 14.6 in
Power Requirements 100V, 50-60Hz

Посетители также интересовались

НЕ ВСЕ ПРОДУКТЫ ДОСТУПНЫ ВО ВСЕХ СТРАНАХ
ДОСТУПНОСТЬ И РЕГУЛЯТОРНЫЙ СТАТУС ПРОДУКЦИИ ЗАВИСИТ ОТ РЕГИСТРАЦИИ ПРОДУКТА В СООТВЕТСТВИИ С МЕСТНЫМ ЗАКОНОДАТЕЛЬСТВОМ

Что означает регулярный статус продукта:
IVD: In Vitro Diagnostic. Данная продукция предназначена для клинической диагностики in vitro.
ASR: Analyte Specific Reagents. Специфические аналитические реагенты. Аналитические и технические характеристики не установлены.
CE: Продукция, предназначенная для клинической диагностики in vitro и соответствующая директиве Европейского союза (98/79/EC). (Примечание: Оборудование может соответствовать другим директивам Европейского союза, и иметь соответствующую маркировку.)
RUO: Research Use Only. Данная продукция предназначена только для научных исследований и не предназначена для клинической диагностики.
LUO: Laboratory Use Only. Продукция предназначены только для лабораторного использования.
Без регуляторного статуса: немедицинские изделия и изделия, не подлежащие обязательной регистрации в регуляторных органах. Данная продукция не предназначена для клинического применения.