Allegra X-14R, 120V - Microplate ARIES

B08875


Refrigeration unit added to the X-14 Benchtop Centrifuge. Temperature control from 2 - 40° C. Ambient temperature is 10 - 30° C. Refrigeration is CFC-free. Holds up to 10 user-defined programs. The Allegra X-14 benchtop centrifuge is a convenient, reliable workhorse piece of equipment that will speed up your process, cycle after cycle. The X-14 offers BioCertified* features for security from contamination, the ARIES Smart Balance Rotor System for faster setup and run times, and a versatile rotor for accommodating tubes, bottles and microplates. The X-14 has a maximum capacity of 3 L, offers extensive biocontainment options, and a 4 x 750 mL swinging bucket rotor (up to 4 300 x g/4300 rpm). Cell Culture Packages also include 15 mL (set of four) and 50 mL (set of four) conical adapters. Maximum capacity for these adapters is 56x15 mL and 28x50 mL. Blood Sample Preparation Application Packages also include 13 mm (set of four) and 16 mm (set of four) diameter tubes. Maximum capacity is 120x13 mm and 76x16 mm blood tubes per run. BioSafe Aerosolve Canister Packages also include a set of four Aerosolve canisters, four 15 mL conical tube rack, and four 50 mL conical tube racks. Maximum rack capacities are 24x15 mL and 16x50 mL. Microplate Application Packages hold up to sixteen standard microplates or four deep well plates. *BioCertified is a term used to describe products which have been tested and validated to demonstrate containment of microbiological aerosols by an independent third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and containment.

Технические спецификации

Platform Allegra X-12
Maximum Speed 10,200 rpm
Maximum g-Force 11,400.00|x g
Acceleration 10 acceleration rates
Deceleration 11 deceleration rates
Timed Run To 99 hrs 59 mins or Continuous run (hold)
Max Capacity Volume Range - 3000 мл
Refrigeration System CFC-Free
Speed Display Actual rotor speed in 10 rpm increments or in RCF (when selected)
Drive Type Cooling Brushless Induction
Temperature Range(s) Copy of Copy of 10
Installation Category II
Weight 128 kg / 282.2 lb
Width 76.2 cm / 30 in
Depth 62.2 cm / 24.5 in
Height 34.3 cm / 13.5 in
Clearances 7.6 cm: side & rear
Humidity Restrictions < 75% (non-condensing)
Power Requirements 120 V, 60 Hz

Посетители также интересовались

НЕ ВСЕ ПРОДУКТЫ ДОСТУПНЫ ВО ВСЕХ СТРАНАХ
ДОСТУПНОСТЬ И РЕГУЛЯТОРНЫЙ СТАТУС ПРОДУКЦИИ ЗАВИСИТ ОТ РЕГИСТРАЦИИ ПРОДУКТА В СООТВЕТСТВИИ С МЕСТНЫМ ЗАКОНОДАТЕЛЬСТВОМ

Что означает регулярный статус продукта:
IVD: In Vitro Diagnostic. Данная продукция предназначена для клинической диагностики in vitro.
ASR: Analyte Specific Reagents. Специфические аналитические реагенты. Аналитические и технические характеристики не установлены.
CE: Продукция, предназначенная для клинической диагностики in vitro и соответствующая директиве Европейского союза (98/79/EC). (Примечание: Оборудование может соответствовать другим директивам Европейского союза, и иметь соответствующую маркировку.)
RUO: Research Use Only. Данная продукция предназначена только для научных исследований и не предназначена для клинической диагностики.
LUO: Laboratory Use Only. Продукция предназначены только для лабораторного использования.
Без регуляторного статуса: немедицинские изделия и изделия, не подлежащие обязательной регистрации в регуляторных органах. Данная продукция не предназначена для клинического применения.